EasyManua.ls Logo

UNI-T UT50B - Accuracy Specifications (DC & AC Voltage); DC Voltage Accuracy; AC Voltage Accuracy

UNI-T UT50B
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
27
Accuracy Specifications(1)
Accuracy: (a% reading + b digits),guarantee for 1 year.
Operating temperature:23
o
C
5
o
C.
Relative humidity:<75%.
Temperature coefficient: 0.1 x (specified accuracy) / 1
o
C.
A. DC Voltage
Remark: Input impedance: 10M
B. AC Voltage
200mV
2V
20V
200V
750V
Remarks:
l Input impedance: 10M.
l Frequency response: 40Hz~400Hz.
l Display effective value of sine wave (mean value
response).
200mV
2V
20V
200V
1000V
100µV
1mV
10mV
100mV
1V
Range Resolution
(0.5%+1)
Overload
Protection
UT50A UT50B UT50C
Accuracy
250VDCor
ACrms.
(0.8%+2)
1000V DC
or 750V AC
rms.
100µV
1mV
10mV
100mV
1V
Range
Resolution
(1.2%+3)
Overload
Protection
UT50A UT50B UT50C
Accuracy
250V DC or
AC rms
(0.8%+3)
(1.2%+3)
1000V DC
or 750V
AC rms.
Model UT50A/B/C: OPERATING MANUAL