7
Tango 0060 11-2019
Tape a 2nd cup in the back of the
drawer about 1” below the top
“0” the scale with an empty
cup
Insert the empty cup into
the taped cup
Replace the drawer with
both cups in place
Calibrate Grinder Dose
Select “Calibrate Weight” to start co󰀨ee weighing process.
(Adjust grind ne or coarse rst, see previous pages)
Follow screen instructions
Remove drawer
Press conrm to start
Grinds Tamps, and Ejects
Remove and weight the cup
with grounds
1st Sample
See next page
for 2nd grind
cycle