EasyManua.ls Logo

Unic URW295CUR - Battery Electrolyte Level Check and Filling

Unic URW295CUR
155 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Check that the battery solution level is
somewhere between the upper and the
lower limit lines with the battery placed
level.
If solution level is found below the lower
limit line, remove the cap to fill it up with
distilled water (It is available at a gas sta-
tion.)
Tighten the caps securely after the water
has been filled.
Pay attention that the crane body may be
eroded by the battery solution due to leak-
age during operation if solution level
exceeds beyond the upper limit line.
Gas evaporated from the battery solution is inflammable.
Do not bring a fire source close to the battery during battery
mainte-
nance.
And, be sure to disconnect the negative (-) side of battery cor
d.
Battery electrolytic solution contains sulfuricacid so that you may be
blinded or burned by the solution when your eye, skin, or clothes was
stained with the solution.
Wear safety goggles and rubber gloves as a protective measures when
working at battery.
If the solution stuck to your skin or clothes, wash it away with plenty of
water immediately.
In case where it entered into your eye accidentally, see a doct
or for
treatment.
When the crane will not be operated for a long period of time such as
in being stored, charge the battery as follows:
Warm season (May to September)Once a month
Cold season (October to April)Once every 2nd month
3. Check for battery electrolytic solution level / Filling up
Upper limit line
Lower limit line
WARNING
MAINTENANCE AND INSPECTION OF CARRIER
28 - 4