Installation Instructions
ENGLISH
Attention!
Do not mix the heating water with in-
correct concentrations of antifreeze or
anti-corrosion substances! This could

during operation.
La Unical AG S.p.A. will not be held
liable for damage to persons, animals
or objects due to failure to comply with
the above instruction.
- make sure that all the connections are watertight.
- after commissioning the boiler (see par. 3.10) and
bringing the system to the operating temperature,
stop the boiler and repeat the air bleed operations.
- let the system cool down and, if necessary, return
the water pressure to 0.8/1 bar.
(See par. 4.4).
When the system connections have been completed,
the circuit can be lled.
This operation must be performed carefully, respect-
ing the following phases:
- open the radiator vent valves and make sure the
automatic valve is working properly in the boiler.
- open the lling tap gradually, making sure that
the automatic air release valves installed on the
system work properly.
- close the radiator air release valves as soon as
water comes out.
- check the pressure gauge until pressure reaches
approximately 0.8/1 bar.
- close the lling tap and bleed air once again
through the radiator air release valves.

The connection between the appliance
and the domestic waste system must
be made in compliance with the specic
reference standards.
NOTE!
Further details in the section
‘Technical Information’ on the
boiler page of the Unical AG S.p.A.
website.