EasyManuals Logo

unicore UM620 Series User Manual

Default Icon
9 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
UM620 Series Hardware Reference Design
3
3 Power Supply Requirements
Main Supply (VCC)
The voltage range of VCC is 2.7 V ~ 3.6 V.
Notes:
The VCC initial level when power-on should be less than 0.4 V.
The VCC ramp when power-on should be monotonic, without plateaus.
The voltages of undershoot and ringing should be within 5% VCC.
VCC power-on waveform: The time interval from 10% rising to 90% must be within
100 μs ~ 10 ms.
Power-on time interval: The time interval between the power-off (VCC < 0.4 V) to
the next power-on is recommended to be larger than 500 ms.
Backup Supply (V_BCKP)
If the hot start function is needed, users should supply backup power to the module. The
voltage range of V_BCKP is 1.7 V ~ 3.6 V.
Notes:
The V_BCKP initial level when power-on should be less than 0.4 V.
The V_BCKP ramp when power-on should be monotonic, without plateaus.
The voltages of undershoot and ringing should be within 5% V_BCKP.
V_BCKP power-on waveform: The time interval from 10% rising to 90% must be
within 100 μs ~ 10 ms.
Power-on time interval: The time interval between the power-off (V_BCKP < 0.4 V)
to the next power-on is recommended to be larger than 500 ms.
The V_BCKP pin cannot be floating or connected to ground. When V_BCKP is not
used, it should be connected to VCC or connected to backup power.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the unicore UM620 Series and is the answer not in the manual?

unicore UM620 Series Specifications

General IconGeneral
Brandunicore
ModelUM620 Series
CategoryControl Unit
LanguageEnglish

Related product manuals