Why does my Uniden Clock show '0.0' flashing?
- JJames FigueroaJul 26, 2025
The Uniden Clock might display a flashing '0.0' if it's not receiving an echo. Several factors can cause this: the sensitivity adjustment might be set too high or too low, effectively blocking the echo; the transducer could be defective, failing to transmit or receive signals; the transducer might be incorrectly installed, preventing pulse transmission or reception; or the unit itself may be faulty and require repair. To troubleshoot, correctly adjust the Sensitivity Control until numbers appear in the display window showing the correct depth. Try using a known working transducer, ensuring it's wet before immersion. Verify the transducer installation according to the manual's instructions. If these steps don't resolve the issue, the unit may need to be returned for repair.