21
! DANGER OF EXPLOSION !
NEVER USE AN OPEN FLAME TO LEAK TEST.
EXTINGUISH CIGARETTES.
STAY AWAY FROM ANY SOURCE OF IGNITION DURING
THIS PROCESS.
• Prepare a water and soap solution (70/30% mixture) in a bottle ideally with
an applicator brush.
• Ensure temperature control is at the ‘’0’’ position. Open gas supply at
cylinder.
Apply with a brush the solution to all ttings, connections and on the gas
hose.
• If bubbles form, it indicates a leak. In this case, turn off gas supply,
retighten connections. Retest for leaks. If a leak cannot be xed, contact a
qualied technician for inspection and repair.
7. The appliance must be isolated from the building’s gas supply piping
system by closing its individual manual shut-off valve during any pressure
testing of the gas supply piping system at test pressure equal to or less
than 1/2 psig(3.5kPa).
After installation:
• Check ignition of cooktop burners.
• Check ignition of oven burner.
• Visually check tubular burner (oven burner) re-ignition to be sure both rows
of burner ports are relighting each time.
• Check for gas leaks at all gas connections (using a gas detector, never a
ame).
• Check oven bake and convection bake function.
CONNECTING RANGE TO GAS SUPPLY continued