Electrical Installations
3
120V Installation (Cord and Plug Connected Units):
Equipment Modules provided with a factory installed power cord are to be
plugged into a grounding type, 120 volt, receptacle.
The connection of the plug to a 240 volt service will cause the Equipment
Module to operate improperly, create the potential for an electrical hazard,
and will void the warranty.
The electrical supply for cord and plug connected units must include a
suitably rated Ground Fault Circuit Interrupter (GFCI) in compliance with
Article 680-42 of the National Electrical Code. ANSI/NFP70. No other
electrical appliance or fi xture should be used on this circuit.
• Use only dedicated electrical line with 20 amp breaker.
• Do not use an extension cord.
• Always use a weatherproof covered receptacle.
• Do not bury the power cord.
Weather Proof GFCI Kit
Weatherproof Receptacle Cover
Spa Power Cord
120V GFCI
Back View
Incoming Power from Main Panel (Black)
Incoming Neutral from Main Panel (White)
Ground
LOAD
LINE