SECTION C, PAGE 13
If the control was set in C5 for KEYPAD & INITIATION or KEYPAD & KEYLOCK,
the display will remain and the electrodes will stay closed until the system is reset
per C5.
LOW CURRENT: If the measured average RMS welding current in a weld goes
below the LO CUR LIM. the display will show at the end of the display line and
follow the same reset procedure as shown above.
If your control includes SOFT TOUCH, skip
to C11.
C10. CONFIGURE SV0 OUTPUT: The voltage output terminal SV0 can
be assigned to operate in several ways. To select how you want this output to
operate, press:
The display will show:
Press and the display shows:
C10.1 FORGE DELAY: This function is useful when welding alloys that
tend to crack when the nugget is cooled.
Your welding machine has to have a FORGE DELAY valve
system to use this function. This includes a 3-way FORGE
SOLENOID VALVE to quickly exhaust air from the bottom
(return) port of the air cylinder when the FORGE VALVE is
turned on. If it does not have this valve, skip to C10.2.
SVO FUNCTION IS:
NOT ASSIGNED =1
Want to change? Push
the YES or NO button
SVO FUNCTION IS:
NOT ASSIGNED =1
FORGE DELAY =2
INTENSIFIER DELAY=3