EasyManua.ls Logo

Universal Laser Systems VLS2.30 - Specifications

Universal Laser Systems VLS2.30
99 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VLS2.30 VLS3.50
Operating
Environment
Well-ventilated oce (recommended) or clean, light-duty manufacturing
Operating
Temperature
50ºF (10ºC) to 95ºF (35º C) capable
73ºF (22ºC) to 77ºF (25º C) for best performance
Storage Temperature 50ºF (10ºC) to 95ºF (35º C)
Operating Humidity Non-condensing
Electrical Power
Single Phase 110/240V AC, 10/5 Amp, 50/60 Hz
Grounded (earthed) and stable (surge and spike protected)
Particulate/Odor
Outside Ventilated
Exhaust System
High-pressure vacuum blower capable of:
150 CFM (cubic feet per minute) @ 6 inches
static pressure (255m3/hr at 1.5kPa)
250 CFM (cubic feet per minute) @ 6 inches
static pressure (425m3/hr at 1.5kPa)
Computer
Requirements
(See the Installation & Set-up
Guide for more information)
Windows XP or Windows Vista (32 and 64 bit)
2.0 GHz Processor (minimum)
1 GB of RAM (minimum)
40 GB Hard Drive (minimum)
Software
Requirement
Graphics or CAD based
Laser Safety
CO
2
Laser, Interlocked Safety Enclosure = Class 1
Red Diode Pointer = Class 2
6