33
TCC On/Off Solenoid overcurrent error
An over-current condition was detected on the torque converter clutch solenoid.
A short circuit may be present in the solenoid circuit. The controller will attempt
to disable both TCC solenoids until the ignition is turned off.
TCC PWM Solenoid overcurrent error
An over-current condition was detected on the torque converter clutch pressure
solenoid. A short circuit may be present in the solenoid circuit. The controller will
attempt to disable both TCC solenoids until the ignition is turned off.
EPC (PCS) Solenoid overcurrent error
An over-current condition was detected on the line pressure control solenoid. A
short circuit may be present in the solenoid circuit. The controller will attempt to
disable the solenoid with the over-current condition until the ignition is turned off.
Shift Solenoid A (SSA) undercurrent error
Current measured on the indicated shift solenoid was too low, indicating that the
solenoid circuit may be open.
Shift Solenoid B (SSB) undercurrent error
Current measured on the indicated shift solenoid was too low, indicating that the
solenoid circuit may be open.
3-2 D/S Solenoid undercurrent error
Current measured on the 3-2 downshift solenoid was too low, indicating that the
solenoid circuit may be open.
TCC On/Off Solenoid undercurrent error
Current measured on the torque converter clutch solenoid was too low,
indicating that the solenoid circuit may be open. The controller will attempt to
disable both TCC solenoids until the ignition is turned off.
TCC PWM Solenoid undercurrent error
Current measured on the torque converter clutch pressure solenoid was too low,
indicating that the solenoid circuit may be open. The controller will attempt to
disable both TCC solenoids until the ignition is turned off.