Fault light (yellow) display and treatment method
1: Check whether the heat dissipation of the heating plate is
normal, 2: Replace the heating plate
1: Replace the heating plate
The internal
temperature of the
machine is
extremely high
1: Check the cooling fan, 2: Stop heating and spraying, and restart
after 10 minutes
1: Check whether there is any foreign matter falling into the spray
nozzle; 2: Replace the fan motor
1: Check the sensor socket, 2: Replace the sensor
Anti-tilt protection
function
Note: After all the fault lights are on, you need to restart the machine until
the fault lights are off before the machine can work normally.
1:检查散热风扇,2:停止加热和喷花,10 分钟后重启
注意:所有故障灯亮后,需要重启机器直到故障灯灭掉机器才能正常工作。
Power cable connection:
For convenient use, there are power supply cable and power supply ex-cable. power
Supply ex-cable can achieve multiple devices connected, and maximum cascade is