Fault light (yellow) display and treatment method
Display
content
cause of issue
Approach
E01
Heating failure
1: Check whether the heat dissipation of the heating plate is
normal, 2: Replace the heating plate
E02
Uncontrolled
heating
1: Replace the heating plate
E03
The internal
temperature of the
machine is
extremely high
1: Check the cooling fan, 2: Stop heating and spraying, and restart
after 10 minutes
E04
Fan does not turn
1: Check whether there is any foreign matter falling into the spray
nozzle; 2: Replace the fan motor
E05
Bad sensor
1: Check the sensor socket, 2: Replace the sensor
E06
Anti-tilt protection
function
Shut down and restart
Note: After all the fault lights are on, you need to restart the machine until
the fault lights are off before the machine can work normally.
显示内
故障原
处理方
E01
加热失败
1:检查加热板散热是否正常,2:更换加热板
E02
加热不受控制
1:更换加热板
E03
机器内部温度超高
1:检查散热风扇,2:停止加热和喷花,10 分钟后重
E04
风机不转
1:检查喷花口是否有异物掉进去,2:更换风机电
E05
传感器坏
1:检查传感器插座,2:更换传感器
E06
防倾斜保护功
关机重启
注意:所有故障灯亮后,需要重启机器直到故障灯灭掉机器才能正常工作。