Gate Direction
This menu allows to invert the opening direction of the gate without
swapping motor wires and limit switch ones.
dx the gate opens rightwards
Sx the gate opens leftwards
m WARNING: “opening direction of gate” means the direction you
see from the inside.
Motor power
This menu allows adjusting the motor power.
The displayed value is the percentage of max. motor power.
Starting ramp
In order not to stress too much the motor, when the motion starts the
power is gradually increased, until reached the set value or 100% if the
take-off is enabled.
Higher is the set value, longer the length of time of the ramp, that is the
time necessary to reach the value of nominal power.
Start off
When the gate is standstill and it begins moving, the initial inertia must
be faced, therefore, if your gate is quite heavy, it could not move.
In case the SPUNTO (pickup) function is activated, for the first 2 seconds
of motion of each door, the control unit will ignore Pot value and it will
give motor the maximum power command in order to
overcome the gate inertia.
Besides, the second capacitor is inserted in order to increase the power
of the motor.