Safety 1
0020285064_00 aroSTOR Operating instructions 5
If possible, open doors and
windows fully and ensure
adequate ventilation.
Do not use naked flames (e.g.
lighters, matches).
Do not smoke.
Do not use any electrical
switches, mains plugs, door-
bells, telephones or other
communication systems in
the building.
Leave the building immedi-
ately and ensure that others
do not enter the building.
1.4 Risk of death due to
changes to the product or
the product environment
Never remove, bridge or
block the safety devices.
Do not tamper with any of the
safety devices.
Do not damage or remove
any tamper-proof seals on
components.
Do not make any changes:
The product itself
The water and electricity
supply lines
to the expansion relief valve
to the drain pipework
to constructional condi-
tions that may affect the
operational reliability of the
product
1.5 Risk of burns caused by
touching hot surfaces
The outgoing lines and hy-
draulic connections are hot dur-
ing operation.
Do not touch any hydraulic
connections.
Do not touch any air inlets or
outlets.
1.6 Risk of being scalded by
hot drinking water
There is a risk of scalding at
the hot water draw-off points
if the hot water temperatures
are greater than 60 °C. Young
children and elderly persons are
particularly at risk, even at lower
temperatures.
Select the temperature so
that nobody is at risk.
1.7 Preventing the risk of
injury from freezing
as a result of touching
refrigerant
The product is delivered with an
operational filling of R 290 re-
frigerant. This is a chlorine-free
refrigerant which does not affect
the Earth's ozone layer. Escap-
ing refrigerant may cause freez-
ing if the exit point is touched.
If refrigerant escapes, do not
touch any components of the
product.

Table of Contents

Other manuals for Vaillant aroSTOR VWL B 200/5 UK

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vaillant aroSTOR VWL B 200/5 UK and is the answer not in the manual?

Vaillant aroSTOR VWL B 200/5 UK Specifications

General IconGeneral
TypeHeat Pump Water Heater
Capacity200 liters
Energy Efficiency ClassA+
Power Supply230V / 50Hz
ErP classA+
RefrigerantR134a
Insulation thickness50 mm
Diameter600 mm
Max Water Temperature65 °C
COP (Coefficient of Performance)3.3 (A15/W10-55 according to EN 16147)