For the installer
ecoMAX 613/2 E
ecoMAX 618/2 E
ecoMAX 622/2 E
ecoMAX 635 E
ecoMAX 824/2 E
ecoMAX 828/2 E
ecoMAX 835 E
GB
Instructions for installation and servicing
ecoMAX
Wall hung room sealed fan assisted condensing boilers
83 41 77_12 GB04.04.qxd 22.09.2004 12:34 Uhr Seite 1

Table of Contents

Other manuals for Vaillant ecoMAX 618/2 E

Questions and Answers

  • M
    Matthew BrewerAug 11, 2025
    Why does my Vaillant ecoMAX 618/2 E go to lockout?
    • K
      Karen WoodAug 11, 2025
      If your Vaillant Boiler goes to lockout, it could be due to several reasons: * There might be no gas supply available, so ensure that the gas supply is on. * There could be insufficient gas, in which case you should check the gas supply pressure. * The gas valve adjustment might be incorrect, requiring you to adjust the gas valve correctly. * The electrode could be defective, so inspect and replace the electrode if necessary. * The ignition lead might have issues, requiring you to check the ignition lead. * The electronic igniter could be defective, so test and replace the electronic igniter if necessary. * There might be blockages in the air inlet duct, so examine the air inlet duct.
  • M
    molinakevinAug 21, 2025
    What to do if the water level is low in my Vaillant ecoMAX 618/2 E?
    • D
      donaldsontiffanyAug 21, 2025
      If the water level is low in your Vaillant Boiler, it could be due to a few reasons. First, there might be no water in the system; in this case, ensure the heating system is full of water and charged to between 1 and 1.5 bar. Refill and vent the system if necessary. Alternatively, the pump could be defective, requiring you to check the pump for proper operation. Finally, the pump lead could be defective, so inspect the pump lead for defects.
  • K
    Kirk OrtegaAug 31, 2025
    What to do if there is no demand to gas valve in my Vaillant ecoMAX 618/2 E Boiler?
    • F
      fpatelAug 31, 2025
      If there is no demand to the gas valve in your Vaillant Boiler, it could be because the electronic board is defective, so you should check the electronic board for faults. Alternatively, the gas valve itself could be defective, requiring you to inspect the gas valve for proper functionality.

Vaillant ecoMAX 618/2 E Specifications

General IconGeneral
Output Power18 kW
Energy Efficiency ClassA
Weight36 kg
Fuel TypeNatural Gas
MountingWall-mounted
ERP RatingA
DHW Output (kW)18 kW
FuelNatural Gas
Central Heating Flow Temperature Range30 - 80 °C
Warranty2 Years
Output18kW
CH Output (kW)18 kW