Operating and display functions 5
0020262548_00 Operating instructions 9
5.1 Information
5.1.1 Reading the system status
Menu Information System status
Under System status, there is a list containing inform-
ation that provides an overview of the current system
status, and current settings that you can change there.
5.1.1.1 System
Menu Information System status Fault status
If no maintenance is required and no faults have oc-
curred, the value No fault appears for Fault status.
If maintenance is required or a fault has occurred, the
value Fault list is shown for Fault status. In this case,
the right-hand selection button is for the Display function.
If you press the right-hand selection button Display, the
list of fault messages appears on the display.
Menu Information System status Green IQ
You can use the function if the connected heat generator
Green IQ is capable of this.
On: The operating mode controls the heat generator in the
heating and cylinder charging mode so that a maximum
gross calorific value utilisation is achieved.
Off: The operating mode is switched off.
Menu Information System status Water pressure
You can use this function to read the water pressure of
the heating installation.
Menu Information System status System status
You can use this function to read the heating installa-
tion's operating mode.
Standby: The heating installation has no heat demand
and is in standby.
Heat. mode: The heating installation heats the living
rooms to the Desired heating temp..
Cooling: The heating installation cools the living rooms
to the Desired cooling temp..
DHW: The heating installation heats the domestic hot wa-
ter in the cylinder to the desired temperature Domestic
hot water.
Menu Information System status Collector temp.
You can use this function to read the current temperature
on the collector temperature sensor.
Menu Information System status Solar yield
You can use this function to read the total solar yield.
Note the contents of the section Display for energy con-
sumption and energy yield ( Page 10).
Menu Information System status Reset solar yield
If you select the Yes setting in the Reset solar yield
function and press the right-hand selection button OK,
you reset the previously totalled solar yield to 0 kWh.
Menu Information System status Environmental
yield
You can use this function to read the total environment
yield.
Note the contents of the section Display for energy con-
sumption and energy yield ( Page 10).
Menu Information System status Reset env.yield
If you select the Yes setting in the Reset env.yield func-
tion and press the right-hand selection button OK, you re-
set the previously totalled environmental yield to 0 kWh.
Menu Information System status Curr. room air
hum.
You can use this function to read the current room air
humidity. The room air humidity sensor is installed in the
system control.
Menu Information System status Current dew
point
You can use this function to read the current dew point.
The dew point indicates the temperature at which the
water vapour in the air condenses and settles on objects.
Menu Information System status triVAI
You can use this function to read whether the heat pump
or the back-up boiler (gas, oil or electricity) is currently
covering the heat demand. The energy manager uses
the triVAI and the comfort criteria to decide which heat
generator to use.
If the value that is read is greater than 1, the heat pump is
better at covering the heat demand than the back-up boiler.
5.1.1.2 ZONE1
Menu Information System status Day temp. heat-
ing
You can use this function to set the desired day temper-
ature for the zone.
Day temp. heating is the temperature that you want to have
in the rooms during the day or when you are at home.
Menu Information System status Day temp. cool-
ing
You can use this function to set the desired day temper-
ature for the zone.
Day temp. cooling is the temperature that you want to have
in the rooms during the day or when you are at home.
Menu Information System status Set-back temp.
heat.
You can use this function to set the desired set-back
temperature for the zone.
Set-back temp. heat. is the temperature that you want to
have in the rooms during the night or when you are away
from home (night mode).
Menu Information System status Room temperat-
ure
If the system control is installed outside of the heat gen-
erator, you can read the current room temperature.
The system control has an integrated temperature sensor,
which determines the room temperature.

Other manuals for Vaillant VRC 700f

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vaillant VRC 700f and is the answer not in the manual?

Vaillant VRC 700f Specifications

General IconGeneral
BrandVaillant
ModelVRC 700f
CategoryBoiler
LanguageEnglish

Related product manuals