Do you have a question about the Vaisala HUMICAP HM70 and is the answer not in the manual?
Humidity Measurement Range | 0 to 100 %RH |
---|---|
Resolution | 0.1 %RH, 0.1 °C |
Display | LCD |
Protection Class | IP54 |
Measurement Parameters | Humidity, Temperature |
Humidity Accuracy | ±1 %RH (0 ... 90 %RH) ±1.7 %RH (90 ... 100 %RH) |
Temperature Accuracy | ±0.2 °C |
Response Time | 15 s (90 % at +20 °C, still air) |
Storage Temperature Range | -40 to +70 °C |
Interface | USB |
Provides information for operating and maintaining the Vaisala HUMICAP Hand-Held Humidity and Temperature Meter HM70.
Details manual codes and their corresponding revision dates and descriptions.
Highlights important safety considerations throughout the manual, including warnings and cautions.
Instructions for recycling applicable materials and disposing of batteries and the unit according to regulations.
Details the terms, conditions, and specific exclusions for Vaisala product warranties.
Overview of the HM70 meter, its components (MI70 indicator and probes), and HUMICAP technology.
Lists and explains the various humidity and temperature related quantities that can be displayed.
Instructions for inserting batteries and recharging the rechargeable battery pack for the indicator.
Step-by-step guide to connecting the probe and powering on the HM70 indicator.
Safety warning regarding disconnecting the probe while the indicator is off.
Explains how temperature differences affect humidity measurements and potential consequences.
Describes the buttons on the M170 indicator and how to navigate menus.
Details the main screen layout, displayed quantities, and status indicators.
Explains how to view measurement data trends in a graphical format.
Guide to accessing and navigating through the various menus and submenus.
Instructions for setting the pressure value for measurements in pressurized environments.
Configuration options for display parameters, including quantities, units, and rounding.
Enables freezing and saving current display readings into the indicator's memory.
Shows the data curve of the last hour, with options for viewing longer graphs.
Covers user interface customization like language selection, power off, and key functions.
Configuration options for the automatic power-off function to conserve battery.
Procedure for reassigning shortcut keys to different device functions.
Adjustments for button click sound effects and backlight behavior.
Instructions for setting the correct date and time for accurate data logging.
Displays technical details and serial numbers for the indicator and connected probes.
Procedure to reset all settings to their original factory defaults.
Steps for starting, setting intervals, and duration for data recording.
Instructions on how to stop data recording and access saved measurement files.
How to view the available memory space and its current usage.
Procedure for clearing all stored data from the indicator's memory.
Using the MI70 Link program to transfer recorded data to a PC for analysis.
Using the MI70 Link program to monitor HM70 readings in real-time on a PC.
Configuring audible and visual alarms for measured quantities.
Optional feature to clean the humidity sensor by heating it to remove chemical interference.
Procedure to activate the chemical purge function on compatible probes.
Optional feature to heat the sensor to prevent condensation and improve response time.
Procedure to activate or deactivate the sensor preheat function.
Overview of using HM70 to calibrate various Vaisala transmitters.
List of necessary connection cables for calibrating different Vaisala transmitter series.
Procedure for calibrating HMD/W 60/70, HMD/W 20/30, and HMP130 series transmitters.
Guide for checking and adjusting HMT100 series relative humidity transmitters.
Procedure for calibrating HMP230/240 transmitters and HMM210 modules.
Steps for checking and adjusting humidity and temperature channels of HMT320 series transmitters.
Instructions for configuring the analog output signal channel for selected quantities.
Overview of probe calibration, factory calibration, and recommended recalibration intervals.
Procedures for adjusting relative humidity measurements, including automatic methods.
Two-point adjustment using LiCl and NaCl references for automatic RH calibration.
Procedure for performing a two-point humidity calibration using a calibrator.
Procedure for performing a one-point humidity calibration using a calibrator.
Procedure for adjusting temperature measurements in one or two points.
How to view the date of the last calibration or adjustment performed on the probe.
Instructions for replacing the probe filter to maintain measurement accuracy.
Steps for replacing the rechargeable battery pack in the MI70 indicator.
List of common error messages and troubleshooting steps for the HM70.
Contact information for Vaisala technical support for questions and assistance.
Procedure for returning the product for repair, including necessary information and packing.
List of Vaisala Service Centers worldwide for calibration, repair, and support.
Detailed specifications for the HMP75, HMP76, and HMP77 humidity and temperature probes.
Details on RH range, accuracies, dewpoint, and absolute humidity measurement specifications.
Details on temperature measurement ranges, accuracies, and response times.
Specifications for calculated variables, including typical ranges and accuracies.
Technical details for the MI70 indicator including operating range, display, power, and interfaces.
List of available accessories, connection cables, carrying cases, and probe accessories.
Diagrams showing the physical dimensions of the MI70 indicator and HMP75, HMP76, HMP77 probes.