4. Dual code (4 eyes principle)
4.1 Programming dual code
Make sure that you programmed a user code (see 2.2) . Make sure that the safe door is open when you
start programming the dual code (ON - master code - ENTER).
.
Step Action Key Signal
1.
Press ON
ON
2.
Press Enter
Enter
3.
Press 7
7
4.
Press Enter
Enter
5.
Key in the user ID, e.g. 1
1
6.
Press ENTER
Enter
7.
Key in the master code, e.g. 567891
567891
8.
Press Enter
Enter
The double code function is now activated.
4.2 Opening with dual code
The lock opens only after entering the master code and the user code which corresponds with the user ID
as programmed in 4.1.
Step Action Key Signal
1.
Press ON
ON
2.
Key in the master code, e.g. 567891
567891
3.
Press Enter
Enter
4.
The opening window period starts, you hear an audible
signal and the green lamp illuminates every 5 seconds
5.
Key in the user code which corresponds with the user
ID as programmed, e.g. 111111
111111
6.
Press Enter
Enter
Open the handle within 5 seconds, the safe is open.