NOTE: As a last resort, if you need a longer delay because of a more
than 10 meters length of the vacuum and air pressure and low flow
conditions, could be increased by an external timer.
PRECAUTIONS:
Do not modify the probe position; the correct height is obtained
by securing it as closely as possible to the end of the probe.
The high-level detector must be situated at the level where the
adhesive covers the tip of the probe slightly. If the probe is re-
calibrated to the level with the probe fully covered, there may be
a risk of adhesive overflow and high air filter wear due to
adhesive splash during the filling process.
It is necessary to secure the reference conductor connection to
the ground of the unit (probe red cable). Its disconnection could
cause that the system becomes unstable.