3
1C WHEEL POSITION CHECK
One problem exclusive to the present model VCWS14 table (1985 or later) is that the
microswitch will get stuck on the stops. This usually occurs when the table is first turned on
and is not warmed up. To determine if this is the problem, look between the red wheel and the
table near the control box. The microswitch wheel should be visible. Look to see if it is resting
on one of the stops. If the microswitch is stuck, the control box will never get the signal to
reset its timing, and the red wheel will not rotate until it is repositioned. To reposition the red
wheel, carefully push it about one inch in the counter clockwise direction. A click will be heard
when the microswitch wheel drops off the stop. Turn the table off and on to reset the control
box. If the microswitch gets stuck on the stop again, increase the wheel rotation speed. After
the work sample begins to function correctly, refer to part 1A to correctly the wheel speed.