Vespera Pro Instruction Manual v1.0 EU US CA 2023-12 7
remove the filter and reassemble. If the problem persists, contact support
Note:
• There is a visual marker with the letter D located on the inside of the filter for easy
identification when the filter is not mounted on the product.
• For optimal storage, we recommend storing the filter in its original plastic box.
• Cleaning and maintenance must be performed with caution. Only use wipes specifically
intended for optical lenses.
Vespera Pro AC021 Solar Filter
1. never point Vespera Pro at the sun without a Vaonis solar filter installed
2. ensure the product is level
3. only handle the filter by its edge to avoid dirtying or damaging it
4. an "alert" window may appear:
if the instrument detects too much light, the observation will be interrupted for safety
reasons. Ensure the filter is properly positioned
if the instrument detects the solar filter was removed, the observation will be
interrupted for safety reasons. Ensure the filter is properly positioned
Installing the filter
1. Turn the product on.
2. Connect to Vespera Pro via the Singularity application.
3. In the application, go to the "space center" page.
4. Click on Solar Pointing
for the first observation, read the information, then press Close
5. Select your observatory.
6. Press the start button: the arm will open to 90°.
7. Remove the cover located on the front end of the optical arm by pressing the button provided for
that purpose.
8. Position the AC021 solar filter.
9. If properly assembled
a filter icon and the name of the filter, "SOLAR", will appear under the product image