3
Warning for users with im-
plants (e.g. pacemakers,
Mixer and safety guard are
equipped with strong mag-
nets.
The mixer may only be used, cleaned and maintained by
trained personnel over 14 years of age. Always observe
local laws and regulations, paying particular attention to
the operator’s age, and physical and mental condition.
The constant noise level of the workplace of the operator
is lower then 70 dB (A).
The mixer is designed for commercial use in kitchens,
catering outlets and bakeries.
The mixer must not be used in an explosive atmosphere.
The mixer may only be used as specied in this manual.
The mixer is designed for manufacture of pro-
ducts which do not during processing cause
reactions or emit substances which may be
detrimental to the user.
Putting your ngers in the bowl while the mix-
er is running may cause injuries.
The electrical connection must only be carried
out by a certied electrician.
Lifting equipment should always be used to
move the mixer.
When the mixer is moved, it should be in an
upright position at all times.
Powdery ingredients:
Do not pour powdery ingredients into the
bowl from a great height.
Bags of e.g. our should be opened at the
bottom, down into the bowl.
Do not increase to maximum speed too quickly.
Install the machine to insure there is enough workspace
for normal use and maintenance.
The work oor where the machine is installed must be
rm, even and level.
The mixer must be mounted with rubber feet, to eliminate
both shaking and rusting. If the floor is not completely
even, spacers can be inserted under the mixer’s feet to
ensure the machine is level.
The machine is placed directly on the oor.
THE MACHINE MUST BE BOLTED TO THE FLOOR
Load per leg not to exceed
ERGO60 2500 N
ERGO100 3200 N
ERGO140 4000 N
AR200 4500 N
The ambient temperature around the machine must not
exceed 45
º
C.
Connection to power
Before the mixer is connected to power, check that the
voltage printed on the machine label are correct in rela-
tion to the installation site. The machine label is located
on the top right side of the mixer.
The mixer is supplied with a 3 m long power cable.
Commissioning
The machine, bowl, tools safety guard and lling chute
must be cleaned before use – see section on Cleaning,
page 6.
Net weight of the machine
ERGO60 330 kg
ERGO100 450 kg
ERGO140 500 kg
AR200 510 kg
Area on safety guard with magnets.
Area on machine with
magnets