FC 3500 DC Fan Control
Document no.:150304 Version: 1.2
Page 13 of 23
6 Programming Parameters
To access the parameter mode;
· Switch the unit off with the ON/OFF key.
· Press the LOWER key for more than 10 seconds.
· You are asked to enter an access code.
Use the RAISE and LOWER keys to enter a digit.
Use the FAN key to move on to the next digit.
The access code is 671.
· If the code is entered correctly you will see P10.
· The access mode will remain active for five minutes after leaving the parameter mode.
After entering the parameter mode, select a parameter by pressing the RAISE or LOWER key. After
selecting the desired parameter press the FAN key to view the value of the selected parameter.
By pressing the FAN key simultaneously with the RAISE or LOWER key the value of de selected
parameter can be changed. The changed value(s) of the parameters will be stored into the memory
after leaving the parameter mode for 30 seconds.
The next pages show the parameter table. Within this table the following notes are applicable
(placed after the parameter numbers).
· These parameters are only active with monitoring system (PC).
· To use humidity-control, a humidity sensor must be connected to Optional Sensor1. Is this
humidity sensor a RH95/2 sensor, than connect as follows;
+12V to pin3 (dc+) of RH95/2 (V+ Supply humidity sensor),
Signal to pin2 (rh+) of RH95/2 (Signal 0-1Vdc = 0-100%RH) and
GND to pin1 (dc-) of RH95/2 (Common 0V)
Also set the Optional sensor1 input selection jumper J30 to volt, see connections