1.4.1 Automatic mode
1. Press the On/Off button to switch on the device.
1
2. Press the Change Mode button and select the option for 'automatic'.
3. The temperature selection keys are disabled.
2
4. Press the button for Fan Speed and select one of the options low/medium/high/automatic.
5. Press the On/Off button to turn off the device. The selected mode remains in memory.
1.
In this mode the machine manages the compressor, heat pump and fan speed entirely automatically
by comparing the set temperature with the internal temperature according to table A.
Table A:
1.4.2 Cold mode
1. Press the On/Off button to switch on the device.
2. Press the Change Mode button and select the option for 'cold'.
3. Press the selection buttons to set the ambient temperature on the desired value between 18°C
and 30°C.
2
4. Press the button for Fan Speed and select one of the options low/medium/high/automatic.
5. Press the On/Off button to turn off the device. The selected mode remains in memory.
1.4.3 Dehumidification mode
1. Press the On/Off button to switch on the device.
2. Press the Change Mode button and select the option for 'dehumidification'.
3. Press the selection buttons to set the ambient temperature on the desired value between 18°C
and 30°C.
4. The fan speed selection button is disabled.
5. Press the On/Off button to turn off the device. The selected mode remains in memory.
1.4.4 Ventilation mode
1. Press the On/Off button to switch on the device.
2. Press the Change Mode button and select the option for 'ventilation'.
3. Press the selection buttons to set the ambient temperature on the desired value between 18°C
and 30°C.
2
4. Press the button for Fan Speed and select one of the options low/medium/high/automatic.
5. Press the On/Off button to turn off the device. The selected mode remains in memory.
1.4.5 Heat pump mode
1. Press the On/Off button to switch on the device.
2. Press the Change Mode button and select the option for ' .
3. Press the selection buttons to set the ambient temperature on the desired value between 18°C
and 30°C.
2
4. Press the button for Fan Speed and select one of the options low/medium/high/automatic.
5. Press the On/Off button to turn off the device. The selected mode remains in memory.
.
heat pump'
Internal
temperature
T < 20°C
Operating
mode
Set point
Heat pump
ventilation
Dehumidification
ventilation
Cold
20°C < T < 25°C T > 25°C
20°C 22°C 25°C