EasyManua.ls Logo

Veeder-Root TLS-450PLUS - Gilbarco TS-1000 POS and PAM Systems; TLS Console Software Requirements; Veeder-Root Hardware Requirements (Ref. Table 2); Gilbarco POS and Dispensing System Requirements

Veeder-Root TLS-450PLUS
59 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
POS App Guide DIM Installation Examples
21
Gilbarco TS-1000 POS and PAM Systems
The Veeder-Root Gilbarco TS-1000 DIM and DIM installation kit supports the Gilbarco TS-1000 and any POS
system using the Gilbarco PAM (Pump Access Module) dispenser controller and Gilbarco dispensers.
TLS CONSOLE SOFTWARE REQUIREMENTS
TLS-350R with BIR Software Requirements
• System software Version 17 (or higher)
• DIM software 349634-003C (or later)
TLS-450/TLS-450PLUS with BIR Software Requirements
• TLS-450 System software Version 2.x (or higher)
• TLS-450PLUS System software Version 6.x (or higher)
• BIR option required (TLS-450)
VEEDER-ROOT HARDWARE REQUIREMENTS (REF. TABLE 2)
The following equipment is required to interface the TLS to the TS-1000 POS:
• One Gilbarco Current Loop Dispenser Interface Module for up to 3 current loops
• One installation kit for each current loop
GILBARCO POS AND DISPENSING SYSTEM REQUIREMENTS
• Gilbarco dispenser distribution box, PA02420000000
• Gilbarco dispenser distribution box, PA02610000010
• Gilbarco dispenser distribution box, PA02610000020
• Gilbarco pump controller, model PA02410000000
• Gilbarco Transac System 1000 Console, model PA0240000000
• Gilbarco Transac System 1000 Console, model PA02400001010
• Excentus Reward Fuel Controller™, Gilbarco Dispenser Interface, V1.0.160 (Excentus P/N 080 - Veeder Root
Kit) is required.
SPECIFIC LIMITATIONS
• Up to 48 Gilbarco single product or blending dispenser fueling positions are supported. Dispensers that feature
a blender and a single-product dispenser at one fueling position are not supported.
• Only Gilbarco dispensers are supported.
• In-dispenser credit card readers in these POS systems are not supported by the Gilbarco Current Loop Dis-
penser Interface Module.
• The Gilbarco Current Loop Dispenser Interface Module does not support Gilbarco G-Site applications.
WIRING TO A UNIVERSAL DISTRIBUTION BOX INTERFACE
The diagram in Figure 5 is a typical interconnection diagram for a PAM or Transac System 1000 interface (a
PA0261 distribution box is shown, the PA0241 is slightly different).

Table of Contents