Operating Instructions
VEGABAR 64
Foundation Fieldbus
Document ID:
28259
Process pressure/
Hydrostatic
p

Table of Contents

Other manuals for Vega VEGABAR 64

Question and Answer IconNeed help?

Do you have a question about the Vega VEGABAR 64 and is the answer not in the manual?

Vega VEGABAR 64 Specifications

General IconGeneral
ModelVEGABAR 64
TypePressure Transmitter
Output Signal4 ... 20 mA/HART, Profibus PA, Foundation Fieldbus
Process ConnectionThreads - Flanges - Hygienic fittings
Process Temperature-40 ... +150 °C
Ambient Temperature-40 … +80 °C
Material (Wetted Parts)316L, Ceramic
Housing Material316L Stainless Steel, Plastic
Protection RatingIP66

Summary

For your safety

2.1 Authorised personnel

Operations must be done by trained personnel; PPE required.

2.2 Appropriate use

VEGABAR 64 is for pressure measurement; use must be according to manual.

2.3 Warning about misuse

Inappropriate use can cause hazards like vessel overfill or damage.

2.4 General safety instructions

Instrument requires strict observance of regulations; must be operated flawlessly.

2.8 Safety instructions for Ex areas

Note Ex-specific safety info for installation and operation in Ex areas.

Product description

Mounting

4.2 Mounting steps

Details steps for welding socket, sealing/screwing in threaded/flange versions.

Connecting to power supply

5.1 Preparing the connection

Covers safety, power supply selection, connection cable, cable gland, and screening/grounding.

5.2 Connection procedure

Step-by-step guide for connecting single/double chamber housing.

5.3 Wiring plan, single chamber housing

Provides wiring illustrations for single chamber housing, non-Ex and Ex-ia versions.

Set up with the indicating and adjustment module PLICSCOM

6.3 Adjustment system

Details the indicating and adjustment elements and key functions.

6.4 Setup procedure

Outlines setup for level or process pressure measurement, including unit selection.

Setup with PACTware and other adjustment programs

7.2 Parameter adjustment with PACTware

Guides on using PACTware and VEGA DTM for parameter adjustment.

Maintenance and fault rectification

8.2 Remove interferences

Operator is responsible for removing interferences; lists common causes of malfunction.

Fault messages via the indicating/adjustment module

Lists common fault messages (E013, E017, E036, E041, E113) and their remedies.

Related product manuals