In many cases, installation place should be examined by an authorized
electrician for determining the correct cable section and length.
Control that no electricity is available in any terminal prior to making any
electrical connections.
In case of any doubt, interrupt the main electricity supply from the fuse
panel.
Scrape the insulation outside of the electrical panel for about 5 cm and
connection cables for about 1 cm with a suitable tool. Electrical cable
should not be damaged during this transaction.
Place electrical cables inside any of device cable inputs and place ends
besides the connector. Carefully connect connection cables to electrical
connection terminals in accordance with electrical connection scheme.
Completely tighten screws of connection blocks and pay attention not to
place cable insulations below connection screws. Loose connections may
heat the cable.
Electrical cable should be secured in accordance with TSE standards in
terms of placement on the wall and protection.
Device and installation should be controlled by an authorized electrician at
least once in two years due to weakening as the result of use and ageing
like in ll electrical devices.
Do not supply electricity until device front cover is closed.
Device pressure safety switch is placed as closed at factory exit in terms
of safety. Pressure safety switch must be opened prior to opening the
device front cover. Otherwise, device shall not perform the heating
operation!