-40-
Problem Detection and Service
EN
Failure
Reason
Solution
Who?
Device not
operates,
hot water
is not
available.
Not LCD
screen view
(BLUE S)
Power LED
does not lit
on the
electronic
card (BLUE)
Electricity
interrupted or
device fuse blown.
Pressure safety
switch blown in the
device.
Electronic card
failure
Control the electricity or
control the device fuse.
Customer
Control the pressure
safety switch.
Technician
Technician
Control the electronic
card.
Very low
water flow.
Water tap or
showerhead filter
is blocked.
Remove filter, clean lime
and purify particles by
washing.
Customer
Device inlet water
filter is blocked.
Remove, clean and
re-install the filter in the
device.
Customer
Sometimes
water
comes cold,
sometimes
hot.
Device air bubble
sensor system
automatically
activates and
deactivates.
After few seconds, air
bubbles shall be
removed from the device
and system shall auto-
continue operation.
Device
auto-
eliminates
the
failure.
E01 or
Red and
blue flashes
Outlet water
temperature sensor
cable is displaced.
Control the sensor and
its cable.
Technician