Do you have a question about the Velleman DVM 890L and is the answer not in the manual?
Type | Digital Multimeter |
---|---|
DC Current Range | 200µA, 2mA, 20mA, 200mA, 10A |
Diode Test | Yes |
Continuity test | Yes |
Continuity Buzzer | Yes |
Transistor test | Yes |
Transistor hFE Test | Yes |
Overload protection | Yes |
Power supply | 9V Battery (6F22) |
DC Voltage Range | 200mV, 2V, 20V, 200V |
DC Voltage accuracy | ±0.5% of rdg ±2 digits |
AC Voltage Range | 200V, 750V |
AC Voltage accuracy | ± 1.2% of reading ± 10 digits |
DC Current accuracy | ±1.0% of rdg ±2 digits |
Resistance Range | 200Ω, 2kΩ, 20kΩ, 200kΩ, 2MΩ |
Resistance accuracy | ±0.8% of rdg ±2 digits |
Battery test | 1.5V/9V |
Display | 3.5 digit LCD, max. indication 1999 |
Lists and describes the key features and capabilities of the digital multimeter.
Outlines essential safety rules and precautions for operating the multimeter safely.
Explains the rotary switch used to select various functions and ranges on the multimeter.
Details the push-button power switch and the Auto Power-Off feature for battery life extension.
Details the four input jacks, their connections, and overload protection limits.
Step-by-step instructions for connecting and performing DC voltage measurements, including notes on overrange.
Step-by-step instructions for connecting and performing AC voltage measurements, including safety notes.
Instructions for measuring DC current, including connection details, ranges, and fuse information.
Instructions for measuring AC current, including connection details, ranges, and fuse information.
Instructions for measuring resistance, including connection, range selection, and notes on overrange.
Instructions for measuring capacitance, including connection to input sockets and polarity.
Instructions for performing diode tests and continuity checks, including buzzer indication.
Instructions for testing transistor hFE values, including lead insertion and display interpretation.
Instructions for measuring temperature using a K-type thermocouple or the built-in sensor.
Explains the Auto Power-Off function that turns the meter off after 15 minutes of inactivity.
Provides general specifications including maximum display, measuring method, operating temperatures, and accessories.
Details the ranges, resolution, accuracy, input impedance, and overload protection for DC voltage measurements.
Details the ranges, resolution, accuracy, input impedance, frequency range, and overload protection for AC voltage measurements.
Details the ranges, resolution, accuracy, overload protection, and maximum input current for DC current measurements.
Details the ranges, resolution, accuracy, overload protection, frequency range, and maximum input current for AC current measurements.
Details the ranges, resolution, and accuracy for resistance measurements, including notes on the 200MΩ range.
Details the ranges, resolution, and accuracy for capacitance measurements.
Details the range, description, test conditions, and accuracy for transistor hFE testing.
Details the ranges, temperature ranges, accuracy, and resolution for temperature measurements.
Details the ranges, descriptions, and test conditions for diode testing and audible continuity testing.
Provides step-by-step instructions for replacing the 9V battery in the multimeter.
Provides guidance on replacing the fuse, specifying the correct type and rating.