EasyManua.ls Logo

Velleman DVM851 - 9.2 DC CURRENT; DC Current Measurement Specifications; 9.3 AC VOLTAGE; AC Voltage Measurement Specifications

Velleman DVM851
98 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DVM851
V. 03 23/10/2015 10 ©Velleman nv
9.2 DC CURRENT
Do not measure current in circuits with voltages > 600V
Range
Resolution
Accuracy
200µA
0.1µA
1% of rdg 2 digits
2mA
1µA
20mA
10µA
200mA
100µA
1.5% of rdg 2 digits
10A
10mA
3% of rdg 2 digits
Overload protection by fuse: 200mA range F 500mA/600V, 10A range
F10A/600V.
9.3 AC VOLTAGE
Do not measure circuits that may contain voltages > 600V
Range
Resolution
Accuracy
200V
100mV
1.2% of rdg 10 digits
600V
1V
Frequency range: 40Hz to 400Hz.
9.4 DIODE & CONTINUITY
Do not conduct diode- or continuity measurements on live
circuits.
Range
Description
If continuity exists (less than 60), built-in buzzer will sound
Displays the diode's approx. forward voltage drop
9.5 RESISTANCE
Do not conduct resistance measurements on live circuits.
Range
Resolution
Accuracy
200
0.1
0.8% of rdg 2 digits
2k
1
20k
10
200k
100
2M
1k
1.0% of rdg 2 digits
Maximum open circuit voltage: 3.2V