DVM898
V. 01 06/04/2017 8 ©Velleman nv
Warning: This device was designed in accordance with EN 61010-1
pollution degree 2. This implies that certain restrictions in use apply that
are related to pollution which can occur within the environment of use. Refer
to the table above.
This device is only suitable for measurements in Pollution
degree class 2 environments.
9. Specifications
This device is not calibrated when purchased!
Regulations concerning environment of use:
Use this meter only for measurements in CAT I, CAT II, CAT III and CAT IV
environments (see §7).
Use this meter only in a pollution degree 2 environment (see §8).
Ideal working conditions include:
temperature: 0 °C to 40 °C (32 °F to 104 °F)
relative humidity: max. 80 %
altitude: max. 2000 m (6560 ft)
voltage ........................................................................... 600 V
fuse protection
F0.5 A/600 V, 5 x 20 mm
F15 A/1000 V, 5 x 20 mm
power supply ................................................. 1 x 9 V 6F22 (incl.)
display ............................................................ LCD, 6000 counts
display dimensions ................................................... 60 x 28 mm
over-range .......................................................................... yes
continuity buzzer .................................................................. yes
diode test ............................................................................ yes
low-battery indication ........................................................... yes
ranging mode ...................................................... auto + manual
data hold ............................................................................ yes
backlight ............................................................................. yes
auto power-off ..................................................................... yes
dimensions ..................................................... 177 x 92 x 40 mm
weight (with battery) ......................................................... 320 g
storage environment
temperature ................................................. -20 °C to 60 °C
humidity ............................................................ < 90 % RH
test lead probe ......... CAT III 1000 V/CAT IV 600 V, 15 A; L = 75 cm