DVM898
V. 01 06/04/2017 9 ©Velleman nv
9.1 DC VOLTAGE
Do not measure circuits that may contain voltages
> 600 VDC or > 600 VAC
range
resolution
accuracy
60.00 mV
0.01 mV
± (0.8 % rdg + 2 digits)
600.0 mV
0.1 mV
± (0.5 % rdg + 2 digits)
6.000 V
1 mV
60.00 V
10 mV
600.0 V
100 mV
600 V
1 V
± (0.8 % rdg + 2 digits)
Overload protection: 600 V DC or AC rms
Impedance: 10 MΩ, > 100 MΩ for 60 mV/600 mV range
9.2 AC VOLTAGE
Do not measure circuits that may contain voltages
> 600 VDC or > 600 VAC
range
resolution
accuracy
60.00 mV
0.01 mV
± (1.2 % rdg + 3 digits)
600.0 mV
0.1 mV
6.000 V
1 mV
± (0.8 % rdg + 3 digits)
60.00 V
10 mV
600.0 V
100 mV
600 V
1 V
± (1.8 % rdg + 3 digits)
AC true rms
Frequency range: 40 Hz-1 kHz
Overload protection: 600 V DC or AC rms
Impedance: 10 MΩ, > 100 MΩ for 60 mV/600 mV range
9.3 DC CURRENT
Do not measure circuits that may contain voltages
> 600 VDC or > 600 VAC
range
resolution
accuracy
600 µA
0.1 µA
± (1.2 % rdg + 2 digits)
6000 µA
1 µA
60 mA
10 µA
600 mA
100 µA