B. PROGRAMMING SELECTOR and SHOCK SENSOR SENSITIVITY
ADJUSTMENT & TESTING :
ENTER PROGRAMMING MODE :
1. Turn the ignition switch on - off.
2. Then turn the valet switch on - off 3 times. There will be a chirp to indicate enter step 1.
3. From step 1 to step 2, step 2 to step 3 and step 3 to step 4 please turn the valet switch on -
off enter.
Valet Switch On -Off
Time
Chirp
Reminder
Select Press button I with 1
chirp confirmation
Press button II with 2
chirp confirmation
Step 1 : 1 chirp Passive/Active Passive Active
Step 2 : Valet on-off 2 chirp Chirp on/off On Off
Step 3 : Valet on-off
again
3 chirp Siren / Horn Siren Horn
Step 4 : Valet on-off
again
4 chirp Enter shock sensor
sensitivity
adjustment &
testing
Exit shock sensor
sensitivity adjustment
& testing. And save the
desirable sensitivity
Choose different level
of shock sensor
sensitivity
STEP 1 : PASSIVE / ACTIVE ARMING SELECTOR
The selector is used to program the passive or active arming feature. Select 'On' (press button
I), the system is in passive mode. That means each time when you leave your motorcycle and
turn the ignition off, the LED will begin to fast flashing, after 15 seconds the system will
automatically armed itself.
Select 'Off' (press button II), the system is in active mode. That means the system will not
automatically armed itself, unless you press the arm button.
STEP 2 : CHIRP SELECTOR
While arm or disarm the system, an audible chirp shows the system's condition. The chirp can
select as your desire. Select 'On' (press button I). There will be audible chirp(s), in arming or
disarming the system.
Select 'Off' (press button II). There will be silent arming and disarming.
STEP 3 : SIREN / HORN SELECTOR
This system allows the user to select siren or horn as the audible warning device. Select 'On'
(press button II). The system must connect with a siren as to send the audible warning.
Select 'Off' (press button II). You must connect the horn to the system. Optional relay needed.
STEP 4 : PROGRAMMING SHOCK SENSOR SENSITIVITY MODE :
To horn button
To horn
White/Black wire from alarm
To Battery + 12V
85
30
86
87
87a