Installation and Operation Requirements - HES140
ENGLISH
3.1.2 With Lowered Ceiling
APPLIANCE CLEARANCES WITH SINGLE
WALL PIPE CONNECTOR
Canada USA
A 14" (356 mm) 14" (356 mm)
B 13" (330 mm) 13" (330 mm)
C 11" (279 mm) 11" (279 mm)
L 72" (1829 mm) 72" (1829 mm)
Ve
Ho
L
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada USA
A 6" (152 mm) 6" (152 mm)
B 13" (330 mm) 13" (330 mm)
C 6" (152 mm) 6" (152 mm)
L 72" (1829 mm) 72" (1829 mm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES
17
FROM PIPE CONNECTOR
WITH SINGLE WALL PIPE CONNECTOR
DISTANCES
17
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada USA Canada USA
D 18" (457 mm) 18" (457 mm) D 9 ¼" (235 mm) 9 ¼" (235 mm)
E 19" (483 mm) 19" (483 mm) E 19" (483 mm) 19" (483 mm)
F 18" (457 mm) 18" (457 mm) F 12 7/8" (327 mm) 12 7/8" (327 mm)
17
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances
above mentioned.