Installation and Operation Requirements - HES140
ENGLISH
2.2 Specifications
Recommended log length 16 in (406 mm) north-south
Maximum log length
11
17 in (432 mm) north-south
Flue outlet diameter 6 in (150 mm)
Recommended connector pipe diameter 6 in (150 mm)
Type of chimney ULC-S629, UL 103 HT (2100 °F)
Minimum chimney height 12 feet
Baffle material Vermiculite
Approved for alcove installation Yes
Approved for mobile home installation
12
Yes
Type of door Simple, glazed, with cast iron frame
Type of glass Ceramic glass
Particulate emission standard
13
EPA / CSA B415.1-10
USA standard (Safety) UL 1482, UL 737
Canada standard (Safety) ULC-S627
Canada standard (Safety) ULC-S627
11
North-south: ends of the logs visible, East-west: sides of the logs visible.
12
Mobile homes (Canada) or manufactured homes (USA): The US Department of Housing and Urban Development describes “manufactured homes”
better known as “mobile homes” as follows; buildings built on xed wheels and those transported on temporary wheels/axles and set on a permanent
foundation. In Canada, a mobile home is a dwelling for which the manufacture and assembly of each component is completed or substantially
completed prior to being moved to a site for installation on a foundation and connection to service facilities and which conforms to the CAN/CSA-
Z240 MH standard.
13
Tested and certied in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and draft ASTM WK47329-14. Based on ALT-125
sent by EPA on February 28th, 2018.

Related product manuals