Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4 30
e. Log Grate
The log grate is designed to keep logs in place and
allow proper air circulation around the fire.
This fireplace was designed to be used with the grate
supplied by Olympia Chimney & Venting.
WARNING! RISK OF FIRE.
Use only the integral grate supplied by
Olympia Chimney & Venting.
f. Firebrick & Refractory
The firebrick and refractory are supplied to contain
and radiate heat and provide an attractive interior.
They will break down over time and will need
occasional replacement. Small hairline cracks and
discoloration are normal and do not affect its safety.
WARNING! RISK OF FIRE.
DO NOT burn fireplace without refractory
or firebricks. Use only the refractory and
firebrick supplied by Olympia Chimney & Venting.
g. Fireplace Screen
The fireplace screens are provided to control sparks.
Keep the screens closed when the fireplace is in use.
WARNING! RISK OF FIRE
OR BURNS.
Screen will not prevent burning material
from falling out of the fireplace. Screen pulls or
handles may be hot.
h. Flue Damper
The flue damper must be in the fully open position
when burning solid wood fuel or vented gas logs
during the operation of this fireplace
WARNING! RISK OF FIRE AND
ASPHYXIATION.
Open damper prior to operating fireplace
with solid wood fuel or vented gas logs. A closed
damper overfires the fireplace and spills smoke and
flames into the room.
NOTE: When operating the fireplace with approved
unvented gas logs, the damper must be in the fully
closed position.
i. Glass Doors
Glass doors are optional
WARNING! RISK OF FIRE.
Only install doors supplied by Olympia
Chimney & Venting
WARNING!
RISK OF FIRE AND SMOKE.
A fireplace equipped with doors should
only be operated with doors fully open or doors fully
closed. If doors are left partly open, gas and flame
may be drawn out of the fireplace opening.
j. Chimney Fire
In the event of a chimney fire:
Have the chimney and adjoining structure
inspected by qualified professionals. Olympia
Chimney & Venting recommends that
Certified professionals conduct a minimum of
an NFPA 211 Level 2 inspection of the
chimney.
Replace components of the chimney and
fireplace as specified by the professionals.
Ensure all joints are properly engaged and
the chimney is properly secured.
WARNING! RISK OF FIRE.
A chimney fire can permanently damage
your chimney system. Failure to replace
damaged components and make proper repairs can
cause a structure fire.