Ventis Forever Firebox – OCV-RR-36/42 – 07-10-2020 rev4 5
4. Fireplace & Chimney Location
Location of the fireplace will affect performance.
Install within the warm airspace enclosed by the building envelope as this will help to produce draft.
Installing the fireplace in a basement is not recommended.
Endeavor to penetrate the roof at its highest point as this will minimize wind loading.
Locate the Chimney Termination Cap away from trees, adjacent walls or buildings, other structures,
uneven roof lines or obstructions.
Minimize the use of offsets (elbows).
Take into consideration the attic joists when selecting a space for the fireplace.
Avoid installing the fireplace near doors or walkways.
Take into consideration the chimney termination requirements in the chimney section of this manual.
5. Equipment, Tools, & Hardware
6. Inspect the Fireplace & Components
WARNING! RISK OF FIRE
AND/OR EXPLOSION!
DO NOT install damaged,
incomplete, or substitute components as this
can affect the fireplaces safe operation.
Inspect the fireplace and its components for
damage.
Report any damaged components directly to
your dealer.
Read all these instruction prior to starting the
installation.
Use of any parts or materials not specified in this
installation manual may not provide a listed
system and may void the warranty. Do not
attempt matching components with another
manufacturers products. Do not use damage or
modified parts.
7. Fireplace System
This fireplace system requires the following
items:
Refractory Panels (3) - included
Refractory Bricks (18) included
Refractory Brick Base - included
Fire screen included
Stainless Steel Grate included
Protective Hearth Strips included
8 Ventis Class-A Pipe sold separately
Ventis Attic insulation shield sold separately
Ventis Firestops sold separately
Ventis Termination Cap sold separately
Tools
:
Reciprocating Saw Plumb Bob
Keyhole Saw Level
Drill Tape Measure
Hammer Caulk Gun
Metal Snips Screwdrivers
Equipment:
Ladder
Safety Glasses
Protective Gloves
Hardware:
#8-1 ½ & 2 ½ Screws
Framing Nails
Roofing Nails
High-Temp Sealant
Silicone Sealant

Table of Contents