REPLACING THE REFRACTORY PACKAGE
1. Open the damper and remove the handle stub (faucet). Use an Allen key wrench to loosen the Allen bolt in the
base of the damper handle stub. Pull the handle off the damper rod.
2. Remove the andirons; one 7/16" hex head bolt each.
3. Remove the throat hood; swing its bottom edge forward and
then
slide the hood to one side until the trailing
end drops from its supports. Take it out of the stove.
4. Use a hammer to tap the two wedges upward and out of the stove