11. Remove/Replace Cold Tank Sensor
11.0 The cold tank sensor is extremely reliable
and rarely needs replacing. Its function
is to control the cold water temperature by
turning the compressor on or off as needed.
11.1 Remove the top cover of the cooler (sec. 3)
11.2 Remove the float assembly )sec. 4)
11.3 Remove the silicon rubber sealing ring
11.4 Remove the silicon over flow tube
11.5 Carefully lift off the insulting foam
from the cold tank