PWC – 500/1000/1010/1500
PureWaterCooler
Copyright 2006 Vertex Water Products
The sanitization procedure is performed to reduce/eliminate any bacteriological
growth in the cooler tanks and dispensing plumbing. Bacteriological growth
can be the cause of some taste and odor in the water.
The procedure is as follows:
• Mix 1 teaspoon of common household bleach (5.25%) in 2 gallons of
clean water.
• Unplug the cooler from the power source.
• Drain all water from the cooler tanks.
• Pour the sanitizing solution into the main (cold temperature) tank until full.
• Open all spigots to allow sanitizing solution to fill the dispensing faucets.
Close the spigots.
• Let the sanitizing solution stand in the cooler for 10 minutes.
CAUTION: Leaving the sanitizing solution in the cooler for more
than 10 minutes can cause taste problems in the water.
• Completely drain the sanitizing solution from all the tanks per section 10
• Fill the main (cold temp.) tank with clear tap water to rinse out the
sanitizing solution.
• Completely empty the rinse water from the tanks.
• The cooler is now sanitized and ready for filling with filtered water.
12. Sanitization Procedure