Power Rating | 10 kVA |
---|---|
Active Power | 10 kW |
Input Frequency | 50/60 Hz |
Output Frequency | 50/60 Hz |
Topology | Double Conversion Online |
Efficiency (ECO Mode) | Up to 98% |
Input Voltage | 380/400/415 VAC |
Efficiency | 94% |
Battery Type | VRLA or Lithium-ion |
Battery Runtime | Varies based on battery configuration |
Communication Ports | USB, RS232 |
Communication Interface | SNMP |
Form Factor | Tower |
Dimensions (H x W x D) | Width: 440 mm, Depth: 600 mm |
Covers general user safety, multiple power inputs, and battery handling.
Explains how the UPS system controls its operation under various conditions.
Details how multiple UPS modules can be connected in parallel.
Describes the different operational modes of the UPS system.
Details Normal, Battery, Bypass, Maintenance, and ECO modes.
Covers parallel redundancy, LBS, and common battery string modes.
Covers constant current/voltage charging and float charge for batteries.
Details temperature effects and battery protection features.
Details battery low pre-warning and End of Discharge protection.
Covers environmental and mechanical requirements for UPS installation.
Guidelines for choosing appropriate locations for UPS and batteries.
Provides procedures for connecting power cables to the UPS.
Defines cable sizing and maximum current ratings for UPS connections.
Recommends cable sizes and UPS I/O switch capacities.
Comprehensive list of UPS alarm messages and their descriptions.
Introduces operating procedures and critical safety precautions.
Essential checks before starting and the initial start-up interface.
Step-by-step guide for starting the UPS in normal operation mode.
Procedure for starting the UPS using battery power directly.
Procedure to transfer load back to inverter from maintenance bypass.
Steps to completely shut down the UPS and disconnect power.
Introduces batteries and covers crucial safety precautions for handling.
Steps to start parallel UPS systems from a switched-off state.
Procedures for operating the parallel system in maintenance bypass mode.
Steps to isolate and reintegrate UPS modules in parallel systems.
Steps to completely shut down UPS modules in a parallel system.
Detailed procedure for installing internal batteries in standard UPS.
Procedure for installing internal batteries in UPS with side cabinets.
Guidelines for maintaining the UPS batteries, including checks and cleaning.