- 11 -
7. As shown in Figure 2: Install the return pipe.
8. Put the suction tube and the return tube into the container.
9. Turn on the power switchReturn valve is now in a state vertically
upwardsThe pressure regulating knob is at the maximum position at
this timeWater will drain out of the return pipe.
10. Turn the return valve clockwise to horizontal. At this time the
machine starts to pressurize. The pressure gauge pointer shows about
3000psiat the same time, the motor stops working.
11. Trigger the spray gun to start sprayingAt this time the motor starts
to workThe pointer of the pressure gauge is kept at about 2000 psi.
TIPS
1. Pressure regulating valveAdjust the pressure regulator clockwise to
pressurize the machine.
2. Backflow valveBackflow valve vertically upward: the machine is in
the backflow stateRelease the pressure state; The backflow valve is
adjusted to the horizontal in a clockwise direction: the machine is
workingIncrease the pressure state.
3. Question: What kind of oil does the 450 plunger sprayer use?
Answer: Any oil with lubricating effect is fine.
4. When do I need to add oil and how much oil do I need to add?
Answer: Before using the machine each time, you need to add about
5 drops of lubricating oil to the oil filler port.
5. What kind of material can be sprayed by the 450 plunger sprayer
Answer: non-particle free material with good fluidity.