- 11 -
stop.
When the machine is in “WASH” or “AUTO mode, if the digital displayer
shows “— —” with alarm and machine stoppingand keys on the operation
panel will be locked. That means the proximity switch is damaged or not in
correct position. Change it or put it in the correct positoin.
When the digital display shows “NL” with alarm and machine stopping,
means the belt of beater motor system is skidded.
If pushing the handle for more than 1 minutehardness window on the
screen will show“Cb” the buzzer will screams and the machine stop.
Under “AUTO or “STANDBY” statusif mix lackhardness window on the
screen will show “CL”and hardness alternatelythe buzzer will screams for
20 seconds
The number “01” will flash if just 1 day left for the setting cleaning cycle.
When the cleaning cycle is over, the window will shows "OVER", and the
buzzer works intermittently. Then you just can use "WASH" and "PUMP"
functions. The refrigeration function is locked, and only can be unlocked
after switch power off and on again. The cleaning cycle will count anew.
Less cooling,no cooling, or cooling over one hour still ice cream not
forming, the screen will display”ERR”, and sound of “BEEP” will continue.
BMake Ice Cream
1)MAKE SURE THE MACHINE IS CLEAN AND SANITIZED BEFORE
MAKING ICE CREAM.
aPrpare some sanitizing solution with warm water(temperature between
50 and 60),pour it into the hopper and clean the wall of hopper.
bTurn on the power switch,and then press and operate for 5
minitues.
cPut an empty pail under the dispensing door,Pull down the handle for 3
seconds,and then return back by hand.Repeat it in this way for 6 times to
clean the mix pump assembly thoroughly.
dDraw out all sanitizing solution from machine and turn off .
eTake off the 4 screws from dispensing door,then remove the dispensing
door assembly.Disassemble it, and put them into the sanitizing solution to

Related product manuals