- 22 -
between the reference and the new measurement.
5. To exit the Relative mode, briefly press this " " button again.
The symbol " " disappears.
Note:
1. When you use Relative mode, the actual value of the object under test
must not exceed the full-scale value of the present range.
2. To avoid wrong measurement results, never enter Relative mode when
Data Hold mode is active.
3. When the display shows " OL ", it means over range.
4. Except for capacitance function, the meter enters manual ranging in
the present range when you enter the Relative mode.
5. For frequency, duty cycle, diode, continuity, and inrush current
measurement functions and non-contact ac voltage detection functions,
Relative mode is not available.
6. In dc current measurement function, the " " button is used to
zero the display.
MIN MAX Mode
The MIN MAX mode stores minimum and maximum input values. When
the input goes below the stored minimum value or above the stored
maximum value, the meter stores the new value.
To use the MIN MAX mode:
1. Make sure that the meter is in desired function or range.
2. Press the " " button to enter MIN MAX mode. The display
shows the maximum reading of all readings taken since entering this mode,
and " " is shown on display as an indicator.
Press this " " button to toggle between the minimum reading