- 12 -
Magnetic sensitive
switch damaged
Replace the magnetic
sensitive switch
The ice guide plate is
not reset
Reset ice guide plate
E2
Ice making is
normal
The fourth ice cycle
stops
Replace the magnetic sensitive
switch
There is no
water in the
water-box
The drain plug is not
installed correctly
Install drain plug correctly
External water supply
Check the water supply
The water tank
overflowed into
the refrigerator
External water supply
The water valve above the tank
does not rotate horizontally
Use tap water as a
source of water
The external water pressure is
too high to cause the float valve
to work, reduce the water
pressure or change a new valve
There is water in
the water box
There is no water, nor
does the shower pipe
run
The pump is seriously blocked,
should be replaced or cleaned
The shower pipe is blocked.
Clean it up
Just running
water, not
cooling or a little
cold
There is thin ice on the
ice mold
Increase manufacturing time by
pressing the "+" button on the
operating panel
There is thick ice on the
ice mold
Reduce manufacturing time by
pressing the "-" button on the
operating panel
Some water splashed
into the refrigerator
Rotate and adjust the shower
pipe
The back of the water
box is leaking into the
Adjust the installation position of
the water box