- 13 -
refrigerator
The water is not
cold
The main board is not
powering the
compressor
Replace the mainboard
Compressor failure
Replace compressor
Compressor high
temperature
Replace compressor
Compressor working,
not cooling
Refrigerant leak, need repair
E3
High
temperature
alarm
condensation
temperature sensor is
damage
Replacement
The cooling fan is
blocked by foreign
matter
Remove the barricade
Damage to cooling fan
Replacement
E4
Abnormal
condensation
temperature
sensor
Condensation
temperature sensor
short circuit or open
circuit
Replacement
E5
Abnormal
ambient
temperature
sensor
Ambient temperature
sensor short circuit or
open circuit
Replacement
E6
Lack of water
Interruption of external
water supply
Restore water supply
Water intake solenoid
valve damaged
Replacement