Note:
If the circuit breaker panel box is not far from the transmitter, the
transmission level of the transmitter must be set to level 1. If the
circuit breaker panel box is too far from the transmitter so that it is
impossible to perform detection and locating, you should
appropriately increase the transmission level of the transmitter
according to actual condition.
Increasing the transmission level from level 1 to level 3 with the
" " button increases the detecting distance of the receiver by
a factor of about 4.
Setup of the receiver: selective mode, minimal sensitivity.
Safety cutouts of different manufacturers have different installation
positions for magnetic coils. If no evident signal can be detected by
the receiver, it is recommended to clockwise or counterclockwise turn
the receiver by 90 angle
.
To avoid electric shock, do not touch any naked conductor with hand
or skin.
Requirements:
The circuit must be dead.
A second transmitter is required for this application.
Connect the transmitters as shown in Figure 13.
Carry out this example as described in the application example.
If a shield mat or shield wiring is located above the heating wires, no
ground connection may exist. If required, separate the shield from the
ground connection, and remember to restore the ground connection
after you finish the detection.
Note:
Increasing the transmission level from level 1 to level 3 with the
" " button increases the detecting distance of the receiver
by a factor of about 4.
Error detection for an electrical floor heating ( one-pole application )