Duct system must terminate to the outside (roof or side wall).
DO NOT terminate the duct system in an attic or other enclosed area.
DO NOT use 4” (10.2 cm) laundry-type wall caps.
Use metal/aluminum duct only. Rigid metal/aluminum vent is recommended.
DO NOT use plastic duct.
Always keep the duct clean to ensure proper airow.
Calculate the following gures before installation:
1. Distance from the oor to the ceiling.
2. Distance from countertop/stove to range hood (recommend* 24” to 30”).
3. Height of hood and duct cover.
For the most e󰀩cient & quiet operation:
A distance of 24” to 30” is recommended* between stove top and the bottom of range hood.
It is recommended that the range hood be vented vertically through the roof through 6” or bigger
round metal/aluminum duct work.
The size of the duct should be uniform.
Use no more than three 90° elbows.
Make sure there is a minimum of 24” (61 cm) of straight duct between the elbows if more than one
elbow is used.
DO NOT install two elbows together.
The length of duct system and number of elbows should be kept to a minimum to provide e󰀩cient
performance.
The duct system must have a damper. If roof or wall cap has a damper, DO NOT use damper (if
supplied) on top of the range hood.
Use aluminum foil tape to seal all joints in the duct system.
Use caulking to seal exterior wall or roof opening around the cap. USE 6” ROUND ROOF OR
RECTANGULAR WALL VENT CAP.
IMPORTANT:
Use a rectangular to circular transition to connect range hood to ducting system.
A minimum of a 6” round duct (standard for this range hood) must be used to maintain maximum
airow e󰀩ciency.
Always use rigid type metal/aluminum ducts if available to maximize airow when connecting to
provided duct.
Please use Duct Run Calculation below to compute total available duct run when using elbows,
transitions and caps.
ALWAYS, when possible, reduce the number or transitions and turns in the duct run. If a reducer is
used, install a long reducer instead of a pancake reducer. Reducing the duct size will restrict airow
and decrease e󰀩ciency.
If turns or transitions are required: Install as far away from opening and as far apart, between 2, as
possible.
Minimum mount height between stove top to hood bottom should be no less than 24-inch*.
Maximum mount height between stove top to hood bottom should be no higher than 30-inch*.
It is important to install the hood at the proper mounting height. Hoods mounted too low could result
in heat damage and re hazard; while hoods mounted too high will be hard to reach and will loose
its performance and e󰀩ciency.
If available, also refer to stove top manufacturer’s height clearance requirements and recommended
hood mounting height above range.
Minimum Duct Size:
Round - 6” (use Aluminimum foil tape to properly seal)
9 ¾” x 3 ⅛” Rectangular Exhaust (use Aluminimum foil tape to properly seal)
* Due to different ceiling height congurations, recommended height may not be applicable.
| LUNA6 LUNA | 7
VENTING REQUIREMENTS