Rev AA Warnings and Alarms 7-13
Videojet 1710 Operator Manual
Warnings and Alarms
Level Related Warnings
Note: The UI displays warnings such as “Error sensing ink core low level probe”
and “Error sensing ink core mid level probe” if the probe level readings are not as
expected. For example, an error appears if the mid level probe shows ‘full’ when
the low level probe shows ‘empty'.
Beacon
Indicator
Level
Displayed
Software
Response
Action
Yellow >100% Ink Core Level is high.
Ink and solvent addition inhibited.
Yellow <20% Do the following:
• Shake ink cartridge before fitting
• Fit ink cartridge
Message prompts to shake the cartridge before fitting.
Yellow
< 5%
Do the following:
• Shake ink cartridge before fitting
• Fit ink cartridge
Message prompts to shake the cartridge before fitting.
Red 0% Printing disabled.
Do the following:
• Shake ink cartridge before fitting
• Fit ink cartridge
Message prompts to shake the cartridge before fitting.
Table 7-6: Warnings and Alarms