TECHNICAL CHARACTERISTICSTECHNICAL CHARACTERISTICS
Note: voltage is monitored at the battery terminals.
a) Protection for polarity reversal.
b)
c) Short-circuit protection in the water pump and in the biturbo fan and/
or in its corresponding electrical connections.
Protection for high voltage
e) Working tension: 12 volts
f) Auto switch off for low battery tension
d) Automatic disconnection due to lack of water in the tank.
CONTROL OF THE WATER
the following chart:
LOW WATER LEVEL SENSOR
it informs the operator with a red LED indication and it
stops the operation of the water pump automatically.
Note: After replenishing the water tank the alarm will stop after approximately 3 minutes.
The module controls the operation of the pump cycle. It is showed in
± 35 SECONDS
SELECTABLE
BETWEEN 14
AND 30
SECONDS
IGNITION
OPERATING
WATER PUMP
WATER PUMP
OFF
± 7 MINUTES
OPERATING
WATER PUMP
It monitors the presence of water in the tank; if there is a lack of water,
SEE WATER CYCLE SETTING